NPSH check Cavitation occurs when the pressure at the impeller inlet falls below the vapour pressure. The check compares the NPSH available in the system with the NPSH required by the pump.

Input (Example from chap. 3.3.4)
mbar
kg/m³
m
m
m

Municipal wastewater has an annual average temperature of about 20 °C. Air pressure drops by approx. 12 mbar per 100 m of altitude.

Result
NPSH margin (NPSHA − NPSHR)
– m
NPSH available in the system NPSHA = – m
–
NPSHA = (pb − pD) / (ρ · g) + hgeo − Hv,s
Margin = NPSHA − NPSHR
Reference Technical book, chap. 3.3.2 · The NPSH value
Example Chap. 3.3.4 · Worked example NPSH
Limits Valid for steady-state operation. During start-up and at part load or overload, NPSH_R is higher.